Laser Particle Size Analyzer, Practical Series

  1. User-Friendly Operation, Manual and Automatic Modes
  2. Convergent-light Fourier transform optical path technology
  3. Automatic Optical Path Alignment System
  4. Practical Sample Dispersion System
  5. Audit trail is optional to comply with 21 CFR Part 11

Share the product

설명

The practical series laser particle size analyzer adopts the laser diffraction particle size measurement principle, combined with a highly sensitive annular photoelectric detector, significantly improving test precision. Its unconstrained free fitting technology truly reflects the particle size distribution, guaranteeing the authenticity and accuracy of test results. It is particularly suitable for testing materials with a narrow particle size distribution.

Features

User-Friendly Operation

Both manual and automatic modes are available for flexible selection based on sample characteristics. In specific scenarios (e.g., samples with unknown properties or tests requiring special parameters), users can first conduct a preliminary test in manual mode. After clarifying the sample features and optimal test conditions, formal testing can be performed in automatic mode for efficiency.

Rapid Measurement

Wet dispersion: When set to automatic mode, all operational procedures are executed automatically, including automatic water supply, ultrasonic sample dispersion, stirring, circulation, background calibration, sample testing, data analysis, drainage and cleaning. This dramatically shortens the measurement cycle, with the entire process taking less than 2 minutes.

Dry dispersion: The intelligent operation system supports one-key testing: simply place the sample into the instrument, and all subsequent processes—including dust collection, air supply, and feeding—are executed automatically. This not only reduces the testing workload but also eliminates errors caused by human factors, further enhancing the accuracy and authenticity of test results.

Advanced Optical Path Design

The converging light Fourier transform technology frees scattered light at large scattering angles from the constraints of the Fourier lens aperture. The reduced focal length enhances the instrument’s resolution, while the annular multi-element silicon photodiode ensures the collection of all particle light signals, greatly improving measurement resolution.

PSA-LA2600A/B PSA-LA2600A PSA-LA2600B Optical Path
PSA-LD3003A PSA-LD3003A Optical Path

Automatic Optical Path Alignment System

The automatic alignment system for optical components is equipped with four hybrid stepping motors, with a micro-precision of 0.1μm. This ensures the instrument’s optical path always maintains optimal performance, eliminating the troubles and difficulties of manual optical path adjustment and further enhancing the accuracy and stability of test results.

Practical Sample Dispersion System

Wet dispersion system: The fully built-in wet sample dispersion system integrates mechanical stirring, ultrasonic dispersion and circulation. This guarantees the uniform dispersion and distribution of particles, avoiding issues like uneven particle distribution and sedimentation of large particles caused by long pipelines in external dispersion systems, thus ensuring the representativeness of test results.

Dry dispersion system: The turbulent dispersion technology and normal shock shearing effect achieve thorough particle dispersion, ensuring reliable test performance.

Software

The original unconstrained free-fitting technology collects scattering data during the measurement process. It frees particle analysis from the constraints of fixed functional models, truly reflecting the particle size distribution.

Item Function
Analysis Modes Free Distribution, R-R Distribution, Log-Normal Distribution, Mesh Size Classification, etc., meet the diverse particle size statistical requirements of different industries.
Statistical Methods Volume Distribution, Quantity Distribution
Statistical Comparison It can conduct comparative analysis on multiple test results. By comparing test results of different batches of samples, samples before and after processing, and samples tested at different times, differences can be identified. This is of great practical significance for quality control of industrial raw materials.
User-defined Analysiss Calculate the percentage based on particle size.

Calculate the particle size based on the percentage.

Calculate the percentage based on the particle size range.

These functions meet the representativeness requirements of particle testing across various industries.

Test Report

Laser Particle Size Analyzer, Practical Series testing report 01 Laser Particle Size Analyzer, Practical Series testing report 02 Laser Particle Size Analyzer, Practical Series testing report 03

Specification

Model Wet Laser Particle Size Analyzer, PSA-LA2600A (1) Wet Laser Particle Size Analyzer, PSA-LA2018 Laser Particle Size Analyzer, PSA-LD3003A
PSA-LA2600A PSA-LA2600B PSA-LA2018 PSA-LD3003A
Instrument type Wet Wet Wet Dry
Specification
Measuring range 0.01μm to 1000μm 0.1μm to 1000μm 0.1μm to 450μm 0.1μm to 300μm
Photodetector 87 87 40 40
Accuracy ≤0.5% (CRM D50) ≤1% (CRM D50) ≤1% (CRM D50) ≤0.5% (CRM D50)
Repeatability ≤0.5% (CRM D50) ≤1% (CRM D50) ≤1% (CRM D50) ≤0.5% (CRM D50)
Design principle Laser Diffraction Laser Diffraction Laser Diffraction Laser Diffraction
Analysis principle Mie Scattering
Fraunhofer Diffraction
Mie Scattering
Fraunhofer Diffraction
Mie Scattering
Fraunhofer Diffraction
Mie Scattering
Fraunhofer Diffraction
Standard ISO 13320 ISO 13320 ISO 13320 ISO 13320
Audit trail Optional FDA software Optional FDA software Optional FDA software Optional FDA software
Engineering
Laser Main Laser: Fiber Laser, 639nm, P>2mW
Auxiliary Laser: 405nm, P>2mW
Fiber Laser, 639nm, P>2mW Semiconductor Laser, 635nm, P>2mW High-performance Laser, 632.8nm, P>2mW
Laser safety Class 1 Class 1 Class 1 Class 1
Operation mode Full Automatic
Manual Control
Full Automatic
Manual Control
Full Automatic
Manual Control
Full Automatic
Manual Control
Optical alignment Full Automatic Full Automatic Full Automatic Full Automatic
Test speed ≤2min
Typical testing time: ≤10s
≤2min
Typical testing time: ≤10s
≤2min
Typical testing time: ≤15s
≤1min
Wet dispersion
Ultrasonic Frequency: 40kHz
Power: 60W
Time: ≥1s
Frequency: 40kHz
Power: 60W
Time: ≥1s
Frequency: 40kHz
Power: 60W
Time: ≥1s
/
Stirrer Speed: 0rpm to 3000rpm adjustable Speed: 0rpm to 3000rpm adjustable Speed: 0rpm to 3000rpm adjustable /
Circulate Rated Flow: 3-8L/min
Rated Power: 15W
Rated Flow: 8L/min
Rated Power: 10W
Rated Flow: 8L/min
Rated Power: 10W
/
Sample tank Volume: 450mL Volume: 450mL Volume: 350mL /
Micro-sample cuvette Optional Optional Optional /
Dry dispersion
Dry dispersion / / / Dry-turbulence dispersion mode, normal shock wave shear technique
Sample feeding / / / Automatic Sampler (SOP setting)
Dispersion medium / / / Compressed Air
Technical data
Connect PC, LIMS Yes Yes Yes Yes
Test Report Word, Excel, Image, Text, etc. Word, Excel, Image, Text, etc. Word, Excel, Image, Text, etc. Word, Excel, Image, Text, etc.
Working environment Temperature: 5℃ to 35℃
Humidity: <85%
Temperature: 5℃ to 35℃
Humidity: <85%
Temperature: 5℃ to 35℃
Humidity: <85%
Temperature: 5℃ to 35℃
Humidity: <85%
Storage environment Temperature: -20℃ to 50℃ Temperature: -20℃ to 50℃ Temperature: -20℃ to 50℃ Temperature: -20℃ to 50℃
Power supply 220V, 50/60Hz 220V, 50/60Hz 220V, 50/60Hz 220V, 50/60Hz
Product dimensions (L×W×H) 850mm×390mm×450mm 850mm×390mm×450mm 780mm×365mm×495mm 765mm×450mm×325mm
260mm×285mm×135mm
Net weight 40kg 40kg 40kg 26kg
7kg